Issues / Vol. 15, N 1 (2009) / Articles

High-rise building testing in the wind tunnel with a atmospheric surface boundary


S. G. Kuznetsov

Donbas National Academy of Civil Engineering and Architecture

Annotation: A building or structure located in immediate proximity to another building or structure is in a bit different conditions than a detached building. The State Building Codes contain wind loads for detached buildings only. It might be right as wind loads are considered to be bearable in this case.We have investigated if this statement is correct, i.e we have compared wind loads on a detached high-rise building and wind loads on two side-by-side standing high-rise buildings. The experiments were carried out in the boundary layer wind tunnel of the work group “Aerodynamik im Bauwesen” of Ruhr-University in the town of Bochum (Germany). The atmospheric boundary layer was simulated by high-drag elements and the flow was described by the exponential law. To perform the experiments there were made two similar models of high-rise buildings. The results of the experiments are given in the form of mean and root-mean-square deviations of shape factors.

Keywords: high-rise building, wind tunnel, wind load, atmospheric boundary layer.

Pages: 85-91.

PDF

Link for citation: Kuznetsov, S. G. High-rise building testing in the wind tunnel with a atmospheric surface boundary. – Text : electronic. – In: Metal Constructions. – 2009. – Vol. 15, N 1. – Р. 85-91. – URL: https://donnasa.ru/publish_house/journals/mk/2009-1/10_kuznecov.pdf (date of access: 03.07.2024). (in Russian)


Issue Cover Vol. 15, N 1 (2009)
Journal: Metal Constructions
Publish house: Donbas National Academy of Civil Engineering and Architecture